Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Neuroradiology ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38658472

RESUMO

PURPOSE: To avoid contrast administration in spontaneous intracranial hypotension (SIH), some studies suggest accepting diffuse pachymeningeal hyperintensity (DPMH) on non-contrast fluid-attenuated inversion recovery (FLAIR) as an equivalent sign to diffuse pachymeningeal enhancement (DPME) on contrast-enhanced T1WI (T1ce), despite lacking thorough performance metrics. This study aimed to comprehensively explore its feasibility. METHODS: In this single-center retrospective study, between April 2021 and November 2023, brain MRI examinations of 43 patients clinically diagnosed with SIH were assessed using 1.5 and 3.0 Tesla MRI scanners. Two radiologists independently assessed the presence or absence of DPMH on FLAIR and DPME on T1ce, with T1ce serving as a gold-standard for pachymeningeal thickening. The contribution of the subdural fluid collections to DPMH was investigated with quantitative measurements. Using Cohen's kappa statistics, interobserver agreement was assessed. RESULTS: In 39 out of 43 patients (90.7%), pachymeningeal thickening was observed on T1ce. FLAIR sequence produced an accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 72.1%, 71.8%, 75.0%, 96.6%, and 21.4% respectively, for determining pachymeningeal thickening. FLAIR identified pachymeningeal thickening in 28 cases; however, among these, 21 cases (75%) revealed that the pachymeningeal hyperintense signal was influenced by subdural fluid collections. False-negative rate for FLAIR was 28.2% (11/39). CONCLUSION: The lack of complete correlation between FLAIR and T1ce in identifying pachymeningeal thickening highlights the need for caution in removing contrast agent administration from the MRI protocol of SIH patients, as it reveals a major criterion (i.e., pachymeningeal enhancement) of Bern score.

2.
J Neurosurg ; : 1-15, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38518292

RESUMO

OBJECTIVE: The ventral amygdalofugal pathway (VAFP) provides afferent and efferent connections to the amygdala and spans along some of the frequently traversed intra-axial surgical corridors as a dominant fiber bundle. This study aimed to reveal the frequently overlooked VAFP fibers by examining their courses and connections to the basal forebrain, septal region, hypothalamus, thalamus, tegmentum, and brainstem. METHODS: Ten postmortem human brains were used to display the characteristics of the VAFP, and fiber dissection results were compared with those of tractography. RESULTS: From anterior to posterior, the VAFP was separated into 5 different portions: 1) amygdala-substantia innominata; 2) amygdaloseptal (diagonal band of Broca); 3) amygdalo-thalamic; 4) amygdalo-hypothalamic, intermingling with the medial forebrain bundle and extending to the bed nucleus of stria terminalis; and 5) amygdalotegmental. The results of fiber dissections were confirmed with findings obtained from diffusion tensor tractography. CONCLUSIONS: This study supports the concept that interconnected forebrain, diencephalic, mesencephalic, and brainstem connections of the VAFP form an integrated surgically important network. The fiber dissection findings also provide the neuroanatomical basis for VAFP segmentation, which may help neurosurgeons better appreciate the complex microsurgical anatomy of the amygdalar connections. Amygdala-substantia innominata and amygdalotegmental connections are demonstrated for the first time and clarified within the structure of the VAFP.

3.
Clin Kidney J ; 17(3): sfae033, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38504664

RESUMO

Kidney transplantation, the gold-standard therapeutic approach for patients with end-stage kidney disease, offers improvement in patient survival and quality of life. However, broad sensitization against human leukocyte antigens often resulting in a positive crossmatch against the patient's living donor or the majority of potential deceased donors in the allocation system represents a major obstacle due to a high risk for antibody-mediated rejection, delayed graft function and allograft loss. Kidney-paired donation and desensitization protocols have been established to overcome this obstacle, with limited success. Imlifidase, a novel immunoglobulin G (IgG)-degrading enzyme derived from Streptococcus pyogenes and recombinantly produced in Escherichia coli, is a promising agent for recipients with a positive crossmatch against their organ donor with high specificity towards IgG, rapid action and high efficacy in early pre-clinical and clinical studies. However, the rebound of IgG after a few days can lead to antibody-mediated rejection, making the administration of potent immunosuppressive regimens in the early post-transplant phase necessary. There is currently no comparative study evaluating the efficiency of imlifidase therapy compared with conventional desensitization protocols along with the lack of randomized control trials, indicating the clear need for future large-scale clinical studies in this field. Besides providing a practical framework for the clinical use of the agent, our aim in this article is to evaluate the underlying mechanism of action, efficiency and safety of imlifidase therapy in immunologically high-risk kidney transplant recipients.

4.
Clin Transplant ; 38(3): e15277, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38485664

RESUMO

As the number of patients living with kidney failure grows, the need also grows for kidney transplantation, the gold standard kidney replacement therapy that provides a survival advantage. This may result in an increased rate of transplantation from HLA-mismatched donors that increases the rate of antibody-mediated rejection (AMR), which already is the leading cause of allograft failure. Plasmapheresis, intravenous immunoglobulin therapy, anti-CD20 therapies (i.e., rituximab), bortezomib and splenectomy have been used over the years to treat AMR as well as to prevent AMR in high-risk sensitized kidney transplant recipients. Eculizumab and ravulizumab are monoclonal antibodies targeting the C5 protein of the complement pathway and part of the expanding field of anticomplement therapies, which is not limited to kidney transplant recipients, and also includes complement-mediated microangiopathic hemolytic anemia, paroxysmal nocturnal hemoglobinuria, and ANCA-vasculitis. In this narrative review, we summarize the current knowledge concerning the pathophysiological background and use of anti-C5 strategies (eculizumab and ravulizumab) and C1-esterase inhibitor in AMR, either to prevent AMR in high-risk desensitized patients or to treat AMR as first-line or rescue therapy and also to treat de novo thrombotic microangiopathy in kidney transplant recipients.


Assuntos
Proteínas Inativadoras do Complemento , Transplante de Rim , Rim , Humanos , Transplante Homólogo , Transplante de Rim/efeitos adversos , Aloenxertos , Rejeição de Enxerto/tratamento farmacológico , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/prevenção & controle
5.
Minerva Anestesiol ; 90(3): 154-161, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38305014

RESUMO

BACKGROUND: The erector spinae plane block is a relatively new regional anesthesia technique that is expected to provide some benefits for postoperative analgesia. This study investigated the effects of erector spinae plane block on postoperative opioid consumption in kidney donors undergoing hand-assisted laparoscopic donor nephrectomy for renal transplantation. METHODS: Fifty-two donors scheduled for elective hand-assisted laparoscopic donor nephrectomy were randomly divided into the block (25 donors) and control (27 donors) groups. Donors in the block group received 30 mL of 0.25% bupivacaine under ultrasound guidance, whereas the control group received no block treatment. The primary outcome measure was the amount of fentanyl administered via patient-controlled analgesia at 24 h. Secondary outcomes included the duration of stay, opioid consumption in the post-anesthesia care unit, and pain scores during the recording hours. RESULTS: No significant differences were observed between the groups regarding total opioid consumption converted to intravenous morphine equivalent administered via patient-controlled analgesia (33.3±21.4 mg vs. 37.5±18.5 mg; P=0.27) and in the postanesthesia care unit (1.5±0.9 mg vs. 1.4±0.8 mg; P=0.55). The duration of stay in the postanesthesia care unit (86.3±32.6 min vs. 85.7±33.6 min; P=0.87) was similar between the groups. There was no significant difference between the groups in the postoperative donor-reported NRS pain scores (P>0.05 for all the time points). CONCLUSIONS: Preoperative erector spinae plane block is not an effective strategy for reducing postoperative pain or opioid consumption in patients undergoing hand-assisted laparoscopic donor nephrectomy. Different block combinations are needed for optimal pain management in hand-assisted laparoscopic donor nephrectomy.


Assuntos
Laparoscopia Assistida com a Mão , Bloqueio Nervoso , Humanos , Analgésicos Opioides , Anestésicos Locais , Bloqueio Nervoso/métodos , Dor Pós-Operatória , Nefrectomia , Ultrassonografia de Intervenção/métodos
6.
Diagn Interv Radiol ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38375627

RESUMO

PURPOSE: To determine how radiology, nuclear medicine, and medical imaging journals encourage and mandate the use of reporting guidelines for artificial intelligence (AI) in their author and reviewer instructions. METHODS: The primary source of journal information and associated citation data used was the Journal Citation Reports (June 2023 release for 2022 citation data; Clarivate Analytics, UK). The first- and second-quartile journals indexed in the Science Citation Index Expanded and the Emerging Sources Citation Index were included. The author and reviewer instructions were evaluated by two independent readers, followed by an additional reader for consensus, with the assistance of automatic annotation. Encouragement and submission requirements were systematically analyzed. The reporting guidelines were grouped as AI-specific, related to modeling, and unrelated to modeling. RESULTS: Out of 102 journals, 98 were included in this study, and all of them had author instructions. Only five journals (5%) encouraged the authors to follow AI-specific reporting guidelines. Among these, three required a filled-out checklist. Reviewer instructions were found in 16 journals (16%), among which one journal (6%) encouraged the reviewers to follow AI-specific reporting guidelines without submission requirements. The proportions of author and reviewer encouragement for AI-specific reporting guidelines were statistically significantly lower compared with those for other types of guidelines (P < 0.05 for all). CONCLUSION: The findings indicate that AI-specific guidelines are not commonly encouraged and mandated (i.e., requiring a filled-out checklist) by these journals, compared with guidelines related to modeling and unrelated to modeling, leaving vast space for improvement. This meta-research study hopes to contribute to the awareness of the imaging community for AI reporting guidelines and ignite large-scale group efforts by all stakeholders, making AI research less wasteful. CLINICAL SIGNIFICANCE: This meta-research highlights the need for improved encouragement of AI-specific guidelines in radiology, nuclear medicine, and medical imaging journals. This can potentially foster greater awareness among the AI community and motivate various stakeholders to collaborate to promote more efficient and responsible AI research reporting practices.

7.
Insights Imaging ; 15(1): 8, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38228979

RESUMO

PURPOSE: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. METHODS: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. RESULT: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. CONCLUSION: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. CRITICAL RELEVANCE STATEMENT: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. KEY POINTS: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score ( https://metricsscore.github.io/metrics/METRICS.html ) and a repository created to collect feedback from the radiomics community ( https://github.com/metricsscore/metrics ).

8.
Eur Radiol ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38180530

RESUMO

OBJECTIVE: To evaluate the use of reporting checklists and quality scoring tools for self-reporting purposes in radiomics literature. METHODS: Literature search was conducted in PubMed (date, April 23, 2023). The radiomics literature was sampled at random after a sample size calculation with a priori power analysis. A systematic assessment for self-reporting, including the use of documentation such as completed checklists or quality scoring tools, was conducted in original research papers. These eligible papers underwent independent evaluation by a panel of nine readers, with three readers assigned to each paper. Automatic annotation was used to assist in this process. Then, a detailed item-by-item confirmation analysis was carried out on papers with checklist documentation, with independent evaluation of two readers. RESULTS: The sample size calculation yielded 117 papers. Most of the included papers were retrospective (94%; 110/117), single-center (68%; 80/117), based on their private data (89%; 104/117), and lacked external validation (79%; 93/117). Only seven papers (6%) had at least one self-reported document (Radiomics Quality Score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD), or Checklist for Artificial Intelligence in Medical Imaging (CLAIM)), with a statistically significant binomial test (p < 0.001). Median rate of confirmed items for all three documents was 81% (interquartile range, 6). For quality scoring tools, documented scores were higher than suggested scores, with a mean difference of - 7.2 (standard deviation, 6.8). CONCLUSION: Radiomic publications often lack self-reported checklists or quality scoring tools. Even when such documents are provided, it is essential to be cautious, as the accuracy of the reported items or scores may be questionable. CLINICAL RELEVANCE STATEMENT: Current state of radiomic literature reveals a notable absence of self-reporting with documentation and inaccurate reporting practices. This critical observation may serve as a catalyst for motivating the radiomics community to adopt and utilize such tools appropriately, thereby fostering rigor, transparency, and reproducibility of their research, moving the field forward. KEY POINTS: • In radiomics literature, there has been a notable absence of self-reporting with documentation. • Even if such documents are provided, it is critical to exercise caution because the accuracy of the reported items or scores may be questionable. • Radiomics community needs to be motivated to adopt and appropriately utilize the reporting checklists and quality scoring tools.

9.
Transplant Proc ; 56(1): 93-96, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38171990

RESUMO

BACKGROUND: To investigate the relationship between immunosuppressive treatments and posterior reversible encephalopathy syndrome (PRES) in transplant patients. METHODS: We presented a retrospective study of 4 cases of PRES in transplant patients. Patient records were reviewed to identify potential risk factors, clinical presentations, radiological findings, and immunosuppressive treatments used. RESULTS: Our analysis revealed a potential association between immunosuppressive treatments and the development of PRES in transplant patients. Specifically, we found that adjusting or switching immunosuppressive treatments can improve outcomes and prevent the recurrence of PRES. CONCLUSION: Our findings highlight the importance of recognizing PRES as a potential complication of immunosuppressive treatments in transplant patients. Early detection and management, including a review of immunosuppressive treatments, may improve patient outcomes and prevent further complications.


Assuntos
Inibidores de Calcineurina , Síndrome da Leucoencefalopatia Posterior , Humanos , Inibidores de Calcineurina/efeitos adversos , Imunossupressores/efeitos adversos , Síndrome da Leucoencefalopatia Posterior/induzido quimicamente , Síndrome da Leucoencefalopatia Posterior/diagnóstico por imagem , Estudos Retrospectivos , Sirolimo
10.
Clin Transplant ; 38(1): e15204, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38041471

RESUMO

BACKGROUND AND AIM: Post-transplant diabetes mellitus (PTDM) is associated with an increased risk of post-transplant cardiovascular diseases, and several risk factors of PTDM have been shown in the literature. Yet, the relationship between hepatic and pancreatic steatosis with post-transplant diabetes mellitus remains vague. We aimed to evaluate pancreatic steatosis, a novel component of metabolic syndrome, and hepatic steatosis association with post-transplant diabetes mellitus in a single-center retrospective cohort study conducted on kidney transplant recipients. METHOD: We have performed a single-center retrospective cohort study involving all kidney transplant recipients. We have utilized pretransplant Fibrosis-4, nonalcoholic fatty liver disease fibrosis score, and abdominal computed tomography for the assessment of visceral steatosis status. RESULTS: We have included 373 kidney transplant recipients with a mean follow-up period of 32 months in our final analysis. Post-transplant diabetes mellitus risk is associated with older age (p < .001), higher body-mass index (p < .001), nonalcoholic fatty liver disease-fibrosis score (p = .002), hepatic (p < .001) or pancreatic (p < .001) steatosis on imaging and higher pre-transplant serum triglyceride (p = .003) and glucose levels (p = .001) after multivariate analysis. CONCLUSION: Our study illustrates that recipients' pancreatic steatosis is an independent predictive factor for post-transplant diabetes mellitus including in kidney transplant patients.


Assuntos
Diabetes Mellitus , Transplante de Rim , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/etiologia , Transplante de Rim/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Diabetes Mellitus/etiologia , Fibrose
11.
Acta Radiol ; 65(1): 106-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36862588

RESUMO

BACKGROUND: Multiple sclerosis (MS) and cerebral small vessel disease (CSVD) are relatively common radiological entities that occasionally necessitate differential diagnosis. PURPOSE: To investigate the differences in magnetic resonance imaging (MRI) signal intensity (SI) between MS and CSVD related white matter lesions. MATERIAL AND METHODS: On 1.5-T and 3-T MRI scanners, 50 patients with MS (380 lesions) and 50 patients with CSVD (395 lesions) were retrospectively evaluated. Visual inspection was used to conduct qualitative analysis on diffusion-weighted imaging (DWI)_b1000 to determine relative signal intensity. The thalamus served as the reference for quantitative analysis based on SI ratio (SIR). The statistical analysis utilized univariable and multivariable methods. There were analyses of patient and lesion datasets. On a dataset restricted by age (30-50 years), additional evaluations, including unsupervised fuzzy c-means clustering, were performed. RESULTS: Using both quantitative and qualitative features, the optimal model achieved a 100% accuracy, sensitivity, and specificity with an area under the curve (AUC) of 1 in patient-wise analysis. With an AUC of 0.984, the best model achieved a 94% accuracy, sensitivity, and specificity when using only quantitative features. The model's accuracy, sensitivity, and specificity were 91.9%, 84.6%, and 95.8%, respectively, when using the age-restricted dataset. Independent predictors were T2_SIR_max (optimal cutoff=2.1) and DWI_b1000_SIR_mean (optimal cutoff=1.1). Clustering also performed well with an accuracy, sensitivity, and specificity of 86.5%, 70.6%, and 100%, respectively, in the age-restricted dataset. CONCLUSION: SI characteristics derived from DWI_b1000 and T2-weighted-based MRI demonstrate excellent performance in differentiating white matter lesions caused by MS and CSVD.


Assuntos
Doenças de Pequenos Vasos Cerebrais , Esclerose Múltipla , Substância Branca , Humanos , Adulto , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Sensibilidade e Especificidade
12.
Diagn Interv Radiol ; 30(2): 80-90, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-37789676

RESUMO

With the advent of large language models (LLMs), the artificial intelligence revolution in medicine and radiology is now more tangible than ever. Every day, an increasingly large number of articles are published that utilize LLMs in radiology. To adopt and safely implement this new technology in the field, radiologists should be familiar with its key concepts, understand at least the technical basics, and be aware of the potential risks and ethical considerations that come with it. In this review article, the authors provide an overview of the LLMs that might be relevant to the radiology community and include a brief discussion of their short history, technical basics, ChatGPT, prompt engineering, potential applications in medicine and radiology, advantages, disadvantages and risks, ethical and regulatory considerations, and future directions.

13.
Diagn Interv Radiol ; 30(2): 124-134, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-37789677

RESUMO

PURPOSE: The reproducibility of relative cerebral blood volume (rCBV) measurements among readers with different levels of experience is a concern. This study aimed to investigate the inter-reader reproducibility of rCBV measurement of glioblastomas using the hotspot method in dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) with various strategies. METHODS: In this institutional review board-approved single-center study, 30 patients with glioblastoma were retrospectively evaluated with DSC-MRI at a 3.0 Tesla scanner. Three groups of reviewers, including neuroradiologists, general radiologists, and radiology residents, calculated the rCBV based on the number of regions of interest (ROIs) and reference areas. For statistical analysis of feature reproducibility, the intraclass correlation coefficient (ICC) and Bland-Altman plots were used. Analyses were made among individuals, reader groups, reader-group pooling, and a population that contained all of them. RESULTS: For individuals, the highest inter-reader reproducibility was observed between neuroradiologists [ICC: 0.527; 95% confidence interval (CI): 0.21-0.74] and between residents (ICC: 0.513; 95% CI: 0.20-0.73). There was poor reproducibility in the analyses of individuals with different levels of experience (ICC range: 0.296-0.335) and in reader-wise and group-wise pooling (ICC range: 0.296-0.335 and 0.397-0.427, respectively). However, an increase in ICC values was observed when five ROIs were used. In an analysis of all strategies, the ICC for the centrum semiovale was significantly higher than that for contralateral white matter (P < 0.001). CONCLUSION: The inter-reader reproducibility of rCBV measurement was poor to moderate regardless of whether it was calculated by neuroradiologists, general radiologists, or residents, which may indicate the need for automated methods. Choosing five ROIs and using the centrum semiovale as a reference area may increase reliability for all users.

14.
Diagn Interv Radiol ; 2023 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-38073244

RESUMO

PURPOSE: To systematically investigate the impact of image preprocessing parameters on the segmentation-based reproducibility of magnetic resonance imaging (MRI) radiomic features. METHODS: The MRI scans of 50 patients were included from the multi-institutional Brain Tumor Segmentation 2021 public glioma dataset. Whole tumor volumes were manually segmented by two independent readers, with the participation of eight readers. Radiomic features were extracted from two sequences: T2-weighted (T2) and contrast-enhanced T1-weighted (T1ce). Two methods were considered for discretization: bin count (i.e., relative discretization) and bin width (i.e., absolute discretization). Ten discretization (five for each method) and five resampling parameters were varied while other parameters were fixed. The intraclass correlation coefficient (ICC) was used for reliability analysis based on two commonly used cut-off values (0.75 and 0.90). RESULTS: Image preprocessing parameters had a significant impact on the segmentation-based reproducibility of radiomic features. The bin width method yielded more reproducible features than the bin count method. In discretization experiments using the bin width on both sequences, according to the ICC cut-off values of 0.75 and 0.90, the rate of reproducible features ranged from 70% to 84% and from 35% to 57%, respectively, with an increasing percentage trend as parameter values decreased (from 84 to 5 for T2; 100 to 6 for T1ce). In the resampling experiments, these ranged from 53% to 74% and from 10% to 20%, respectively, with an increasing percentage trend from lower to higher parameter values (physical voxel size; from 1 x 1 x 1 to 2 x 2 x 2 mm3). CONCLUSION: The segmentation-based reproducibility of radiomic features appears to be substantially influenced by discretization and resampling parameters. Our findings indicate that the bin width method should be used for discretization and lower bin width and higher resampling values should be used to allow more reproducible features.

15.
Eur J Radiol ; 167: 111088, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37713968

RESUMO

PURPOSE: To investigate the quality of reporting in radiomics research, with a focus on the most basic technical parameters. METHODS: A PubMed literature search was conducted to identify original studies on radiomics (last search: January 2, 2023). Following a sample size calculation with an a priori power analysis, a random sample of the radiomic literature was collected. In addition to baseline characteristics, the key aspects of radiomic software, resampling, and discretization were evaluated. Agreement between raters was analyzed. Disagreements were resolved through consensus. RESULTS: A sample of 87 publications was evaluated. Most publications (89%; 77/87) were retrospective. They were conducted predominantly with private data (87%; 76/87) at a single institution (77%; 67/87) without external validation (90%; 78/87). 69% (60/87) of the papers reported the radiomic software used (p < 0.001), with nearly half (43%; 26/60) omitting the version. 37% (32/87) reported the resampling size (p = 0.018), while 22% (7/32) did not report using iso-voxel resampling. 34% (30/87) reported the discretization parameters (p < 0.01), but more than three-quarters (77%; 23/30) did not experiment with different discretization parameters. A wide range of discretization parameter values were reported. Most papers (79%; 69/87) failed to report all three essential items simultaneously (p < 0.001). CONCLUSION: Even the essential radiomic parameters that are usually displayed on the user interface of radiomic software tools were poorly reported in radiomics-related publications. This issue of transparency may require additional action from researchers, editors, and reviewers in the form of adopting more stringent reporting standards (e.g., checklists, guidelines).


Assuntos
Lista de Checagem , Projetos de Pesquisa , Humanos , Estudos Retrospectivos , Consenso , Software
16.
Eur Radiol ; 2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37740080

RESUMO

OBJECTIVE: To evaluate the usage of a well-known and widely adopted checklist, Checklist for Artificial Intelligence in Medical imaging (CLAIM), for self-reporting through a systematic analysis of its citations. METHODS: Google Scholar, Web of Science, and Scopus were used to search for citations (date, 29 April 2023). CLAIM's use for self-reporting with proof (i.e., filled-out checklist) and other potential use cases were systematically assessed in research papers. Eligible papers were evaluated independently by two readers, with the help of automatic annotation. Item-by-item confirmation analysis on papers with checklist proof was subsequently performed. RESULTS: A total of 391 unique citations were identified from three databases. Of the 118 papers included in this study, 12 (10%) provided a proof of self-reported CLAIM checklist. More than half (70; 59%) only mentioned some sort of adherence to CLAIM without providing any proof in the form of a checklist. Approximately one-third (36; 31%) cited the CLAIM for reasons unrelated to their reporting or methodological adherence. Overall, the claims on 57 to 93% of the items per publication were confirmed in the item-by-item analysis, with a mean and standard deviation of 81% and 10%, respectively. CONCLUSION: Only a small proportion of the publications used CLAIM as checklist and supplied filled-out documentation; however, the self-reported checklists may contain errors and should be approached cautiously. We hope that this systematic citation analysis would motivate artificial intelligence community about the importance of proper self-reporting, and encourage researchers, journals, editors, and reviewers to take action to ensure the proper usage of checklists. CLINICAL RELEVANCE STATEMENT: Only a small percentage of the publications used CLAIM for self-reporting with proof (i.e., filled-out checklist). However, the filled-out checklist proofs may contain errors, e.g., false claims of adherence, and should be approached cautiously. These may indicate inappropriate usage of checklists and necessitate further action by authorities. KEY POINTS: • Of 118 eligible papers, only 12 (10%) followed the CLAIM checklist for self-reporting with proof (i.e., filled-out checklist). More than half (70; 59%) only mentioned some kind of adherence without providing any proof. • Overall, claims on 57 to 93% of the items were valid in item-by-item confirmation analysis, with a mean and standard deviation of 81% and 10%, respectively. • Even with the checklist proof, the items declared may contain errors and should be approached cautiously.

17.
Turk J Surg ; 39(1): 86-88, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37275935

RESUMO

Renal transplantation could be a challenging operation in patients with haemorrhagic diathesis, with predictable difficulties or even with unpredictable hurdles. Bernard Soulier Syndrome (BSS) is one of the ethiologies of the thrombocytopenia and it is a rare hereditary disease associated with defects of the platelet glycoprotein complex glycoprotein Ib/V/IX and characterized by large platelets, thrombocytopenia, and severe bleeding symptoms. Here, we present a challenging renal transplantation in BSS.

19.
Eur J Radiol ; 165: 110893, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37285646

RESUMO

OBJECTIVE: To evaluate the reliability of consensus-based segmentation in terms of reproducibility of radiomic features. METHODS: In this retrospective study, three tumor data sets were investigated: breast cancer (n = 30), renal cell carcinoma (n = 30), and pituitary macroadenoma (n = 30). MRI was utilized for breast and pituitary data sets, while CT was used for renal data set. 12 readers participated in the segmentation process. Consensus segmentation was created by making corrections on a previous region or volume of interest. Four experiments were designed to evaluate the reproducibility of radiomic features. Reliability was assessed with intraclass correlation coefficient (ICC) with two cut-off values: 0.75 and 0.9. RESULTS: Considering the lower bound of the 95% confidence interval and the ICC threshold of 0.90, at least 61% of the radiomic features were not reproducible in the inter-consensus analysis. In the susceptibility experiment, at least half (54%) became non-reproducible when the first reader is replaced with a different reader. In the intra-consensus analysis, at least about one-third (32%) were non-reproducible when the same second reader segmented the image over the same first reader two weeks later. Compared to inter-reader analysis based on independent single readers, the inter-consensus analysis did not statistically significantly improve the rates of reproducible features in all data sets and analyses. CONCLUSIONS: Despite the positive connotation of the word "consensus", it is essential to REMIND that consensus-based segmentation has significant reproducibility issues. Therefore, the usage of consensus-based segmentation alone should be avoided unless a reliability analysis is performed, even if it is not practical in clinical settings.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Consenso , Carcinoma de Células Renais/patologia , Neoplasias Renais/patologia , Processamento de Imagem Assistida por Computador/métodos
20.
World Neurosurg ; 2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37390902

RESUMO

OBJECTIVE: To determine whether diffusion tensor imaging (DTI) parameters acquired with model-based DTI and model-free generalized Q-sampling imaging (GQI) reconstructions may noninvasively predict isocitrate dehydrogenase (IDH) mutational status in patients with grade 2-4 gliomas. METHODS: Forty patients with known IDH genotype (28 IDH wild-type; 12 IDH mutant) who underwent preoperative DTI evaluation on a 3-Tesla magnetic resonance imaging scanner were analyzed retrospectively. Absolute values obtained from model-based and model-free reconstructions were compared. Using the intraclass correlation coefficient, interobserver agreement was assessed for various sampling techniques. Variables having statistically significant distributions between IDH groups were subjected to a receiver operating characteristic (ROC) analysis. Using multivariable logistic regression analysis, independent predictors, if present, were identified and a model was developed. RESULTS: Six imaging parameters (3 from model-based DTI and 3 from model-free GQI reconstructions) showed statistically significant differences between groups (P < 0.001, power >0.97), with very high correlation to each other (P < 0.001). Age difference between the groups was statistically significant (P < 0.001). The optimal logistic regression model comprised a GQI-based parameter and age, which were independent predictors as well, producing an area under the ROC curve, accuracy, sensitivity, and specificity of 0.926, 85%, 75%, and 89.3%, respectively. Using the GQI reconstruction feature alone with a cut-off of 1.60, an 85% of accuracy was also achieved with ROC analysis. CONCLUSIONS: The imaging parameters acquired from model-based DTI and model-free GQI reconstructions, combined with the clinical variable age, may have the ability to noninvasively predict the IDH genotype in gliomas, either alone or in particular combinations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...